Fly ash sampler sampling

time:2023-11-25 22:42:41Views:

1. Determination of Sampling


The sampling of fly ash sampler is selected on the flue between the outlet of the air preheater and the inlet of the dust collector. The specific installation location should generally meet the following conditions:


The flue gas temperature is less than 370 ℃;


At the straight pipe outer wall of the horizontal flue, and at a height of 1/3 of the flue from the bottom of the flue; Or at the straight pipe side wall of the vertical flue, and at a distance of 1/3 of the flue thickness from the rear wall of the flue;


There are no obstacles in the flue that affect positive sampling;


The representative parts of smoke flow velocity and dust particles;


There is a space outside the flue for the installation of measuring devices and normal operation.


2. Opening of sampling holes


According to the determined sampling location, remove the insulation layer of the flue after shutdown, and cut a 142mm (width) X232mm (height) rectangular hole on the flue wall for welding the rectangular flange.


3. Welding of canopies, flanges, and brackets


Remove the insulation layer of the flue between the canopy and the installation bracket of the measurement unit according to Figure 5, and then weld the canopy, rectangular flange, measurement unit installation bracket, extended angle iron, support angle iron, and pressure regulating valve installation plate separately (the welding position of the extended angle iron and pressure regulating valve installation plate depends on the on-site situation). When welding, it is necessary to ensure that the distance from the bottom edge of the rain shelter to the rectangular flange is 130mm; 2. The installation surface of the rectangular flange is perpendicular to the ground; 3. The distance from the installation surface of the rectangular flange to the flue wall is 350mm; The distance between the installation bracket of the measuring unit and the rectangular flange is ensured by the welding auxiliary connecting plate.


 

手機(jī)導(dǎo)入圖片 1202.jpg

手機(jī)導(dǎo)入圖片 1205.jpg

手機(jī)導(dǎo)入圖片 1204.jpg

If the sampling unit is not installed temporarily, the square holes on the rectangular flange should be covered with the flange cover provided by the manufacturer and tightened with screws to ensure the sealing of the flue during boiler operation.


4. Welding of on-site control cabinet installation bracket


The installation bracket of the control unit can be welded between two measuring units or on a steel column near a certain measuring unit according to the on-site conditions. During welding, the height from the edge of the installation bracket to the on-site walkway or platform surface should be about 1.8 meters.


5. Installation of sampling unit


6. Adjust the sampling tube


According to the different positions of the flue installed in the sampling unit, it is necessary to adjust the sampling tube to ensure that the direction of the intake nozzle of the sampling tube is aligned with the direction of the flue gas flow. Adjustment method: 1. Loosen the nut (1), 2. Loosen the long nut, 3. Pull out the sampling tube in an upward direction until the cylindrical pin on the circular flange of the sampling tube is detached from the installation plate. 4. Rotate the sampling tube according to the flow direction of the throat at the installation position, so that the intake nozzle of the sampling tube is facing the direction of the smoke flow. Then insert the cylindrical pin on the circular flange of the sampling tube into the corresponding positioning space on the installation plate. 5. Tighten the long nut, 6. Finally, tighten the nut (1).


7. Installation of measurement units


Installation method: 1. Place the measuring unit on the installation rack and place a spirit level (provided with the equipment) on the measuring unit section; 2. By adjusting the lifting of the four bolts and rods at the bottom of the measuring unit, combined with the stable horizontal movement of the measuring unit, the ash inlet of the measuring unit is concentric with the lower ash outlet of the sampling unit cyclone dust collector. At the same time, the transition pipe component can precisely connect the lower ash outlet of the sampling unit cyclone dust collector and the ash inlet of the measuring unit; 3. Fine tune the 4 rod bolts at the bottom of the measuring unit, while observing the level of the measuring unit, so that the surface of the measuring unit is in a horizontal state; 4. Tighten the nut of the transition pipe component between the measuring unit and the sampling unit cyclone dust collector; 5. Tighten the four parallel nuts of the rod bolts at the bottom of the measuring unit; 6. Tighten the four tie rod bolts at both ends of the bottom of the measuring unit and tighten the nuts; 7. After the installation of the measurement unit is completed, restore the insulation layer and protective iron sheet on the flue wall.


你可能喜歡看:
The purpose of Fly ash sampler

The purpose of Fly ash sampler

The purpose and function of the Fly ash sampler produced by Lianyungang Lingdong Electromechanical Equipment Co., Ltd. is that the carbon content of boiler Fly ash is an important indicator reflecting the combustion rate of coal-fired boilers in thermal power plants.

Fly ash sampler

Fly ash sampler

The Fly ash sampler is a device used for sampling Fly ash from the tail gas of boilers in thermal power plants, providing a safe and reliable scientific basis for measuring boiler combustion losses in power plants. The Fly ash sampler has been used in household appliance factories, but it is not. This device is easy to operate, has a short sampling time, and can meet user requirements to the greatest extent.

Installation and working engineering of coal powder sampler

Installation and working engineering of coal powder sampler

The installation and operation of the coal powder sampler and mobile coal powder sampler of Lianyungang Lingdong Electromechanical Equipment Co., Ltd. drill holes on the flue, extend the sampling tube into the flue, and make the sampling head face the direction of the incoming smoke flow.

Coal powder sampler

Coal powder sampler

The design of the coal powder sampler adopts compressed air blowing and suction sampling with an air extractor. The sampling speed is controlled by controlling the compressed air pressure and flow rate. The design of the coal powder sampler adopts compressed air blowing and suction sampling with an air extractor, which avoids the problem of clogging of the sampling port and is easy to sample.

drain flash tank

drain flash tank

A drainage expansion vessel is a type of vessel that expands and depressurizes the drainage of the pressure drainage pipeline, separates steam and drainage, and introduces steam into a heat exchanger or deaerator. The drainage expansion vessel consists of two 16m rectangular containers, with the other mainly accepting high-pressure heater emergency drainage and deaerator overflow drainage.

sampling cooler

sampling cooler

Introduction to sampling coolers of soda: Solid sampling cooler is used for power plants, power stations, steel smelting, chemical, textiles, printing and dyeing and other boiler room furnace water and sampling cooler coolant. The sampling cooler can meet the standards of DL/T457-91 in the power industry , Met the sampling test requirements.

Soda sampling cooler

Soda sampling cooler

The steam sampling cooler is suitable for sampling media such as liquids and vapors with high temperatures. The steam sampling cooler adopts a spiral tube (commonly known as a serpentine coil) surface cooling structure. sampling catheters are all used for sampling, which are corrosion-resistant and non polluting.

Various forms of coal powder samplers

Various forms of coal powder samplers

The use of carbon steel material in coal powder samplers has caused many problems, and some manufacturers still encounter these problems when using coal powder samplers. So it is recommended to use stainless steel material at least ---.

Portable constant velocity Fly ash sampler for regular coal powder sampling on the air and coal powder pipeline

Portable constant velocity Fly ash sampler for regular coal powder sampling on the air and coal powder pipeline

The portable constant velocity Fly ash sampler produced by Lianyungang Lingdong Electromechanical Equipment Co., Ltd., also known as the Fly ash constant velocity sampler or the swirling Fly ash constant velocity sampler,

A coal powder sampler can also be referred to as a portable coal powder sampler

A coal powder sampler can also be referred to as a portable coal powder sampler

The manual mobile coal powder sampler produced and manufactured by Lianyungang Lingdong Electromechanical Equipment Co., Ltd. can also be called a portable coal powder sampler. It is mainly used for regular coal powder sampling on the secondary air coal powder pipe in the positive pressure direct blowing coal powder system.