一性一交一口添一摸视频,精品久久BBBBB免费人妻,欧美免费不卡一区二区三区,天天做天天爱夜夜爽毛片毛片

Silencer type
Your location : Home > Product > Silencer type
Roots blower silencer
Roots blower silencer
Roots blower silencer
Roots blower silencer

Roots blower silencer

Roots blower muffler, also known as Roots blower muffler, can be used to reduce the intake/exhaust noise of various types of fans, as well as to reduce the noise of exhaust pipes and other high-pressure fans. Roots blower silencers/eliminators are mainly used for various series of high-pressure centrifugal fans to reduce air intake.
Online inquiry
上一產(chǎn)品 : Induced draft fan silencer
下一產(chǎn)品 : Centrifugal fan silencer
  • Content details

Introduction:


Roots blower muffler, also known as Roots blower muffler, can be used to reduce the intake/exhaust noise of various types of fans, as well as to reduce the noise of exhaust pipes and other high-pressure fans.


Roots blower silencers/eliminators are mainly used in various series of high-pressure centrifugal fans to reduce aerodynamic noise at the inlet and outlet. When installed by the user as required, the noise limit of this product will not exceed 85-90 decibels.

Conclusion - Principle:


Roots blower muffler/suppressor is developed based on the principle of soundproof film silencing. This type of muffler has good acoustic performance and good aerodynamic performance; Reasonable structure, easy to install, it is a high wind resistance honeycomb muffler, which adopts a chamber resistant adhesive straight pipe channel and a cross shaped sound-absorbing plate form, thereby ensuring sufficient noise reduction within a wide frequency band range. The muffler structure is composed of several parallel unit muffler tubes arranged in a row, with holes filled with sound-absorbing materials between the muffler tubes. In order to reduce the radiation sound generated by airflow and shell wall vibration, reinforcement ribs are installed on the outer shell.


The forms of fan silencers, centrifugal fan silencers, and drum induced draft fan silencers all adopt the principle of resistance absorption noise reduction with good results for low frequency and pulsation, as well as micro perforated silencers and impedance composite silencers.


Classification:


Fan silencers are divided into: centrifugal fan silencers, Roots fan silencers, blower silencers, and axial flow fan silencers. Fan eliminators are mainly used to reduce the aerodynamic noise of various fan air outlets, air ducts, and enclosed machine room air intakes.


1. According to the different inlet and outlet structures of the fan, it is divided into circular structures and rectangular structures.


1) The circular junction is divided into two types: type A and type B. Both ends of type A are flange plates, directly connected to the pipeline (i.e. pipeline silencer). Type B is a flange at the end, and the other end is directly vented to the atmosphere (rainproof hood can be installed). It is only suitable for outdoor pipeline ends and enclosed machine room air intakes.


2) The resistance type sound-absorbing plate with a circular structure has a general thickness of 100mm, 150mm, and a sound-absorbing capacity of 15-30dB (A). Under the condition of wind speed of 5-12m/s, the applicable air volume is 1000-50000m3/h. The conclusion is to use impedance two types of noise reduction zones for high-frequency and low-frequency noise reduction, in order to maximize the broadening of the noise reduction frequency band.


Please provide the following information when ordering a fan muffler:


1) Fan model and usage scenario;


2) Fan air volume and wind speed;


3) Size of the nozzle;


Principle:


Based on the frequency spectrum data obtained from inter site testing of various types of industrial wind turbines, the main basis for designing sound absorbing bodies and fluid channels is to determine which frequency range requires a large amount of noise reduction. At the same time, narrow rectangular channels with larger sound absorbing material finishes are used to enhance absorption results. The noise of another fan often has more than one spectral value when there is large noise, and the requirements for noise reduction vary for different spectral bands.


For this purpose, the series of ventilation duct eliminators and drum induced draft fan eliminators are both impedance sound flow type, using a resistive structure that absorbs and suppresses high and low frequency noise, as well as an impedance structure that suppresses and reduces low and high frequency noise. At the same time, two types of absorption and attenuation zones, high-frequency and low-frequency, are used in the resistive channel to maximize the broadening of the noise reduction frequency band and achieve good noise reduction results.


Ventilation duct eliminators and drum induced draft fan eliminators are suitable for various types of centrifugal, axial, Roots fans, and air compressors.


--:


Fans are a type of general mechanical equipment with a wide range of applications. Sales in various industries such as electricity, mining, machinery, metallurgy, and chemical industry all rely on fans. The noise generated by the operation of the fan has become a disaster that affects the health of workers and interferes with the environment- The aerodynamic noise emitted by the air inlet and outlet of fans, especially those in neighboring residential areas, is the main factor polluting the environment and causing public hazards. It has become one of the main targets of noise pollution in our industrial sector in recent years.


Industrial fans are equipment that operates continuously- The International Organization for Standardization (ISO) specifies a noise standard of ≤ 90 decibels for this type of equipment. My standard is the same, which is also the basis for industrial enterprises to continuously meet noise standards. However, without using noise reduction measures, the noise emitted from the fan inlet and outlet into the environment can reach 110-120 decibels, greatly exceeding the standard requirements.


This muffler series is produced as an impedance acoustic flow type. Based on the data obtained from the on-site noise testing of various types of wind turbines in power plants, a large amount of noise reduction is required as the main basis for designing sound absorption film structures and fluid channels in which spectral ranges. At the same time, narrow rectangular channels with large sound absorption material finishes are used to enhance absorption results. We know that the noise of a fan often has more than one spectral value when there is large noise, and the requirements for noise reduction vary for different spectral bands. For this purpose, this product adopts a resistive structure that suppresses high and low frequency noise, as well as an impedance structure that suppresses low and high frequency noise. At the same time, high-frequency and low-frequency noise reduction zones are used in the resistive channel to maximize the bandwidth of noise reduction and achieve good noise reduction results.


Specification and model:

型號(hào)

法蘭內(nèi)徑d(mm)

外徑D

長(zhǎng)度L(mm)

有-長(zhǎng)度M (mm)

-大風(fēng)量(m3/min)

DF-50

50

200

1000

800

1.3/2.5

DF-80

80

250

1200

1000

5/7

DF-150

150

400

1500

1200

10/20

DF-200

200

450

1700

1400

30/40

DF-300

300

600

1900

1600

60/80

DF-350

350

800

2100

1800

120/160

DF-400

400

900

2100

1800

200

DF-500

500

1000

2100

1800

250

Roots blower silencers are mainly used to reduce the noise of axial flow fans. They are generally circular junction silencers, divided into single cavity junction silencers and double cavity junction Roots blower silencers. The sound reduction of ZFD single cavity type is 15-20dB (A), and the sound reduction of ZFS double cavity type is 20-25dB (A). The cross-sectional dimensions are all made according to the universal standard air duct. Micro perforated plates are made of stainless steel or aluminum alloy plates.


風(fēng)機(jī)消-器

型號(hào)

適用風(fēng)機(jī)參數(shù)風(fēng)機(jī)消-器外形參考尺寸阻力損失小于Pa消-量
排風(fēng)量 m3/h法蘭接口mm總長(zhǎng) mm外徑mm
ZFJ33000200-350160060010025-35db(A)
ZFJ66000300-350170060020025-35db(A)
ZFJ88000300-350180070023525-35db(A)
ZFJ1212000400-500180080025025-35db(A)
ZFJ1515000500-600210090026025-35db(A)
ZFJ2020000500-6002200100026025-35db(A)
ZFJ2525000500-6002300100026025-35db(A)
ZFJ3030000500-6002600120028025-35db(A)
ZFJ4040000600-7002800120030025-35db(A)
ZFJ8080000800-10003000160030025-35db(A)
ZFJ100100000800-10003200175030025-35db(A)
ZFJ200200000800-10003200180030025-35db(A)
ZFJ500500000800-12003600200050025-35db(A)
ZFJ800800000800-12004200210050025-35db(A)
ZFJ100010000001200-15005000240050025-35db(A)


你可能喜歡看:
Pipeline silencer

Pipeline silencer

Pipeline silencers are mainly used for silencing the steam emissions of thermal equipment such as boilers and steam turbines in the power generation department. The noise reduction capacity of the pipeline muffler can meet the requirements of the Industrial Enterprise Noise Hygiene Standard.

blower silencer

blower silencer

The blower muffler is mainly suitable for reducing the intake and exhaust noise of Roots series and axial flow series fans. The blower muffler can also be used for noise reduction of exhaust pipes and other high-pressure fans, with a noise reduction amount of 10-20dB (A) and a pressure loss of less than 500Pa.

Centrifugal fan silencer

Centrifugal fan silencer

The centrifugal fan muffler is developed based on the principle of soundproof sheet noise reduction. This type of muffler has good acoustic performance and good aerodynamic performance; Reasonable in structure and easy to install, it is a honeycomb type muffler with high wind resistance. It adopts a chamber resistant adhesive straight pipe channel and a cross shaped sound-absorbing plate form.

Blow pipe silencer

Blow pipe silencer

Blow pipe silencers can be used to eliminate the noise generated by boilers and pipelines during blowing. Box type blow pipe silencers are divided into upper exhaust and partial exhaust, with the upper exhaust type being a box structure and the partial exhaust type being a circular structure.

Steam silencer

Steam silencer

Steam silencers are used for a wide range of steam emission objects in thermal equipment. Various specifications of boiler steam silencers can be designed and manufactured based on the user's extracted steam output, steam pressure, and connection size.

Fan silencer

Fan silencer

Safety valve silencer

Safety valve silencer

The TA type exhaust safety valve silencer is suitable for the safety valves of pressure devices such as PCV/ERV safety valves (power release valves), drum safety valves, superheater safety valves, and reheater safety valves in power plant boilers. The safety valve muffler adopts the principle of spray impedance composite noise reduction, which replaces the smaller diameter control hole with a large hole expansion.

Small hole injection silencer

Small hole injection silencer

A small hole injection muffler is also known as a diffuser. It sprays gas from high-pressure vessels through several layers of small orifice plates to reduce noise. To prevent clogging of small holes and the difficulty of processing small holes, the diameter of small holes can be selected within the range of 1-3 millimeters (which should meet the condition of b>=8d)

Venting silencer

Venting silencer

A venting muffler is designed and developed to suppress noise production during factory pipeline venting and exhaust. The types of mufflers are divided into six main types: vent mufflers, impedance composite mufflers, micro perforated plate mufflers, small hole mufflers, and existing mufflers.

Combination fan silencer

Combination fan silencer

The combination type fan muffler (combination type composite muffler) mainly has a small hole type muffler inserted inside the fan muffler to achieve the desired effect, and the combination mode can be selected as needed. Welcome - Customers come to design and manufacture, or contact us to help you design.

產(chǎn)品動(dòng)態(tài)

Roots blower silencer生產(chǎn)廠家Copyright ? 2012-2023 Lianyungang Lingdong Electromechanical Equipment Co., Ltd all rights reserved

Tel

0518-85370171